Abstract
Background: Premature and sick neonates may require weeks of hospitalization in a noisy neonatal intensive care unit (NICU) environment with sound levels that may reach 120 decibels. The American Academy of Pediatrics recommends a maximum sound level of 45 decibels.
Purpose: To measure sound levels in a level III NICU and to describe contributing environmental factors.
Methods: Descriptive quantitative study. Sound levels were measured using a portable sound meter in an open-bay level III NICU. Contributing environmental factors were recorded and analyzed.
Results: Mean sound levels for day, evening, and night shifts were 83.5, 83, and 80.9 decibels, respectively. Each period of time exceeded the recommended guidelines 90% of the time and was almost double the American Academy of Pediatrics' recommendation. Multiple linear regression findings demonstrated significant factors associated with elevated sound levels including number of neonates, number of people, number of alarms, acuity level, and shift type. Observational data explain 14.5% of elevated sound levels.
Implications for Practice: An understanding of baseline sound levels and contributing environmental factors is the first step in developing strategies to mitigate excessive noise in the NICU.
Implications for Research: Research should focus on effective and sustainable ways to reduce sound levels in the NICU, including inside the isolette, in order to provide an environment that is conducive to optimal growth and neurodevelopment for preterm and sick infants.